At the end of the wake up period the MX60 closes its relays and produces power. At dusk and dawn this will happen many times until there is not enough power from the PV array to keep going. Disabled: The AUX output terminals have no output.
The user can control backlight options using the setup screen shown in Figure 9. Depending on your energy production, you may elect to leave the lighting off or on. There is also a third option called Auto. Tapping any key quickly while in Auto mode will turn the lights on for 30 seconds. Page 11 Voc: This is the open circuit voltage of the PV panels measured at the last wakeup cycle. State: The MX60 has thousands of lines of code. Each operation is called a State.
This number is useful for troubleshooting. This is an optional setpoint and is not required to be adjusted in most installations. OutBack Power Systems does not warrant or guarantee the workmanship performed by any person or firm installing its products.
Registering your products will help us maintain the standard of excellence you expect from us in terms of performance, quality and reliability. Please take a moment to register and provide us with some important information.
Print page 1 Print document 17 pages. Rename the bookmark. Delete bookmark? Cancel Delete. Delete from my manuals? Sign In OR. Previous Page. Next Page. Includes mounting, installation, and product registration 24 pages. Page 2 Maximum Power Point of the array.
The MX60 set points are fully adjustable to allow use with virtually any battery type, chemistry, and charging profile. You have successfully set up your MX60 charge controller for your nominal battery voltage. Page 5 The default charger settings of the MX60 are based on typical sealed lead acid battery systems.
To change these setting simply follow the menu instructions below. Page 8: Multi-Stage Battery Charging This stage reduces the charging voltage to prevent overcharging of the batteries A Float charge follows after the Absorb charge is completed. The MX60 will not re-initiate another Bulk charge if the Float voltage set point is not sustained, however, it will continue to charge the battery until the Float voltage set point is achieved.
Page Troubleshooting Guide 1. Is battery voltage greater than the Absorb voltage set point compensated Absorb voltage? Is the PV voltage greater than the battery voltage by at least 2 volts? The PV voltage has to be at least 2 volts greater than the battery voltage for the initial wakeup. Page 12 When the current limit set point is achieved the MX60 will continue sweeping to maintain the targeted current limit 2.
What is the sweep interval set point?